  Winner2009 full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000 μm/1200μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.

 


Products Description

Brief introduction:

      Winner2009 full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000 μm/1200μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.

 

Main Specifications:

Model Name

                    Winner2009A

                        Winner2009B

Standard

ISO13320-1:2009, GB/T19077.1-2016, Q/JWN001-2024

Principle

MIE scattering principle

Measuring Range

0.01μm-2000μm

0.01μm-1200μm

Channels Number

97

95 (different photo detectors & optical light path)

Accuracy error

<1%   (Deviation of  D50 on national standard sample)

Repeatability error

<1%   (Deviation of  D50 on national standard sample )

Light source

High performance He-Ne Laser (λ= 632.8nm,  P>2MW) Lifetime>25000hours

 

Dispersion

 Method

Ultrasonic

Frequency:40KHz   Power:35W,   Time: ≥1S ,Anti-dry function

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:8L/min    Rated Power:10W

Sample Pool

Volume:350mL

Micro-Sample Pool

Volume: 10mL ( Available)

Operation Mode

Full automatic/ manual control, freely choose

Resolution

Free distribution truly reflect particle size distribution

Optical bench alignment system

Japan Canon lens, Full automatic,precision is up to 0.1um

Software  

function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.

Statistic Method

Volume Distribution, Quantity Distribution

 

Statistic Comparison

Several Testing Results of samples

Different batches of samples testing result,

Samples before and after processing,

Test result of samples in different time.

 

User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries

Test Report

Word, Excel,Photo( Bmp), Text etc

Multiple-language

 Support

Multiple language Support

Intelligent operation

 Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor

Testing speed

<2min/time

Outer dimension

1200mm*370mm*560mm  

Net weight

70 KG

Main Features:

 

1)Winner Patent -Optical path design

Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01μm to 2000μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals.

 

2) Expand Size Range

Winner2009A measurement range significantly expanded to 0.01um, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

 

 3)Full automatic wet dispersion system

The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process.

 

4) Intelligent Operation mode

With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.


5)Automatic Optical path alignment system

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.

 

6)Authoritative calibration method

In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

 

7) Unconstrained free fitting patent technique

Winner original unconstrained free fitting patent technology, particle size analysis is not affected by any functional constraints, truely refelect particle size distribution.


Instrument principle diagram

Winner2009 Auto Wet Dispersion Laser Particle Size Analyzer

Adopt Patents Technology:

1.Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,

2.Optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.

3.Mie scattering principle application patent No.- ZL 2013 2 0812021.4.

4.Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0

 


Instrument Test operation interface:

After the background test, click on Energy spectrum test” in "test view". And the system will display "test view". Observe the Spectral curve and concentration, After the test result becomes stable, click the “save the results”. The System will automatically save the test result at the preset time intervals

Winner2009 Auto Wet Dispersion Laser Particle Size Analyzer

                          Energy Spectrum Test View


Test Report and Its Description:

1) D10 : Particle diameter, < 10% particle volume summation percent of total particle’s volume

2) D50 : Particle diameter, < 10% particle volume summation percent of total particles volume

3) D90 : Particle diameter, < 10% particle volume summation percent of total particles volume

4) DAV:The average particle size of the particle swarm

5) S/V: Volume specific surface area; surface area per unit volume of particles

        

Application:

Winner2009 is widely used in mineral materials, cement, ceramics, chemicals, paint, emulsion, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasive, lubricant, coal, sand, dust, bacteria, cells, food, additives, pesticides, explosives, graphite, photosensitive materials, fuel, and ink metal and non metal powder, calcium carbonate, kaolin, coal water slurry and other powder material.

 Winner2009 Auto Wet Dispersion Laser Particle Size Analyzer


 

 



 





CONTACT US
GET IN TOUCH

Copyright © Jinan Winner Particle Instrument Stock Co., Ltd. All Rights Reserved | Sitemap  

ORDER NOW!